Focus on conductor ampacity, temperature corrections, and protective device selection informed by inverter output and array current. Respect the 120 percent busbar rule when backfeeding a panel, or choose a line-side tap with proper lugs and enclosures when needed. Document grounding and bonding methods clearly, and show rapid shutdown boundaries. Simple, legible one-lines that mirror field reality earn quick approvals and smooth final sign-offs.
Roof structures vary widely, so attachment spacing, spans, and load paths must reflect actual rafters, trusses, and sheathing. Provide engineering where required, acknowledging wind uplift, snow loads, and seismic considerations as applicable. Respect fire department access with clear perimeter pathways and setbacks around ridges and hips. When your layout preserves egress and reduces trip hazards, inspectors recognize the craftsmanship and pass projects with confidence.